93
AT85C51SND3Bx
7632A–MP3–03/06
The control logic of the UVCC pad outputs 2 signals:
• The “session_valid” signal is active high when the voltage on the UVCC pin is higher
or equal to 1.4V.
• The “Va_Vbus_valid” signal is active high when the voltage on the UVCC pin is
higher or equal to 4.4V.
In the Host mode, the VBUS flag follows the next hysteresis rule:
• VBUS is set when the voltage on the UVCC pin is higher or equal to 4.4 V.
• VBUS is cleared when the voltage on the UVCC pin is lower than 1.4 V.
In the Peripheral mode, the VBUS flag follows the next rule:
• VBUS is set when the voltage on the UVCC pin is higher or equal to 1.4 V.
• VBUS is cleared when the voltage on the UVCC pin is lower than 1.4 V.
The VBUSTI interrupt is triggered at each transition of the VBUS flag.
Comentarios a estos manuales