Atmel CAMELIA 8M Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
13
CAMELIA 8M Digital Camera
1986B–IMAGE–03/03
Command Processing after
‘’E=1’’
Each command received by the camera is processed:
If the command is valid:
setting is done
the camera returns: >OK(CR)
If the setting value is out of range (command not valid):
nothing is done
the camera returns: >1
If the syntax is not correct (command not recognized by the camera):
the camera returns: >2
Camera Identification A character string stored in EEPROM gives the product model, its version and its serial
number.
Example: CAMEL_COL_1.6M_01_9851002
stands for: CAMELIA COLOR 1.6M, version 01, serial number 9851002
It is read by sending: !=0(CR)
The serial number is detailed as following:
Figure 8. Serial Number
Customer Identification Customer identification is a character string (25 characters max).
It is set and stored in EEPROM by sending $=xx..xx
It is read by sending !=1(CR)
Customer identification is stored in EEPROM whatever the state of E.
Reading Current Settings When receiving ’!=3(CR)’’ the camera returns its current settings.
98 51 002
Year Number in the week
Week in the year
Vista de pagina 12